Remove the abutment/screw with a reverse rotation friction when it is difficult to use the 1.2 hex driver due to screw deformation by jammed debris in the 1.2 hex connection area, or thread abrasion.
-
Custom tray is used for pick-up type of impression taking. . Asymmetry structure to minimize close interruption . Uses 1.2 Hex Driver . Length : 10mm . Packing unit : pick-up impression coping + Guide Pin
-
Used to create over-denture for edentulous patient. Used when fixed type prosthesis is difficult due to severe bone or soft tissue loss. . Composition of O-ring : for dental lab use (black), for clinic use (orange). . Path recovery to the maximum of 20°. . Post partis coloring in gold . Uses Ball Abutment driver . Packing unit : Ball abutment + Abutment holder + O-Ring (Orange for clinic use) . Tightening Torque: 20Ncm (Narrow) , 30-35Ncm (Regular & Wide)
-
Provides Anchor point for ball abutment on working model. Length : 10mm
-
. Outstanding consistency and Clip-on . Packing Unit : Ball Cap + O-Ring (OR-0450B / OR0450O) . Length : 4mm . Diameter : ø5.0
-
1. Prevention of gingiva creeping ¡¤ Covering of gum in the margin and gingiva retraction ¡¤ Can accurately take impression with widened gum 2. Protection of the patient's tongue ¡¤ Since the protect cap can fall off while biting food with antagonist teeth (sticky food, etc.), be careful not to swallow the cap if fallen.
-
. Implant is placed according to depth of the fixture and direction of the internal hex planned in advance. . Recommended use of UF(II) narrow : 20 times / be careful about excessive torque of 50Ncm or above.
-
HSA (Hybrid SLA) Hex ø2.5 Apex ø2.9 , ø3.4, ø3.9, ø4.5
-
HSA (Hybrid SLA) Hex ø1.7 Apex ø1.6 ø3.0 fixture exclusive for anterior teeth ø1.6 ø3.3 fixture exclusive for anterior teeth ø1.9
-
MNTL (Standard) - length from tip to bend is 25mm and from bend to connection end 25mm MNTE (Extensions) - length from tip to bend is 30 mm and from bend to connection end 50mm
-
. Pick-up type impression coping to take an abutment level impression. . Used with an open tray . Only for Multiunit Abutment . Uses 1.2 Hex Driver . Packing Unit : Pick-up Impression Coping + Guide Pin . Tightening Torque : 5-8Ncm
-
Custom tray is used for pick-up type of impression taking. . Asymmetry structure to minimize close interruption . Uses 1.2 Hex Driver . Length : 10mm . Packing unit : pick-up impression coping + Guide Pin
-
. Used to remove fractured abutment screws by attaching the bar's blade end with the residual surface and turning anti-clockwise.
-
Used to remove fractured abutment screws by inserting the drill to the fixture and turning anti-clockwise 1000 RPM (Narrow: 1200) / in reverse Irrigation is required to prevent excessive heating
-
used to connect the abutment screw (for handpiece)using an abutment screw driver for ratchet.
-
Abutment of cement retained type that uses dental cement to fix prosthesis in place .Abutment and screw are in one-piece structure HDS 4506A | HDS 5506A | HDS 6506A HDS 4512A | HDS 5512A | HDS 6512A
-
. Used for taking impression of solid abutment . Different coloring provides easy identification for abutment diameter . Convenient locking mechanism . Length : 11mm
-
. Stopper must be used for adjusting depth of the frill. it is distinguished by color and number . Surgical Tool 2.0 Diameter for Crestal . Surgical Tool Round Drill and Core Drill for Lateral
-
To place the fixture using an implant connector. DIOnavi Narrow Kit
-
If the fracture remnants of abutment connection are not removed from inside the fixture, tighten inside the remnants and remove abutment by frictional force
-
Used to connect the anchor screw using an anchor screw driver for ratchet
-
Alveolar crest surface is flattened, and soft tissue remaining in the alveolar crest is removed after using the tissue punch.